ADEPT – Digital Panel Meters

ADEPT digital panel meter

Function / Input Type

Model INT4-AH

Suits 50mV, 60mV, 75mV and 100mV shunts. Can be set to accumulate in a timebase of minutes, hours or days.

User Manual

Model INT4-C

Period mode is ideal for bake time and intervals.

User Manual

Model INT4-H

Real time clock mode and up or down timing modes with 3 x contact closure control inputs.

  • Clock mode – HH:MM:SS
  • Day counter mode – number of days elapsed since last reset
  • HH:MM timer mode
  • MM:SS timer mode
  • SSSS timer mode
  • SSSSS.t timer mode
  • MMMM timer mode
  • HH:MM:SS timer mode
  • DD:MM:YY calendar mode
  • MM:DD:YY calendar mode

Model INT4-C

Various counting modes.

  • Simple counting mode
  • Gated counting mode
  • 1 input with up/down control mode
  • 2 inputs up/down mode
  • 2 inputs up/up mode
  • 4 inputs up/up/down/down mode
  • 4 inputs up/up/up/up mode
  • 4 inputs down/down/down/down mode

Accepts different signal types and provides 24V DC sensor excitation as standard.

  • Contact closure
  • NPN
  • PNP/pushpull
  • TTL
  • CMOS
  • Passive coil
  • AC tacho

User Manual

Model INT4-C

Rate mode is ideal for showing…..

  • Frequency
  • Flow rate
  • RPM
  • Instantaneous speed

Production rate mode is ideal for showing real production rates over longer periods.

Accepts different signal types and provides 24V DC sensor excitation as standard.

  • Contact closure
  • NPN
  • PNP/pushpull
  • TTL
  • CMOS
  • Passive coil
  • AC tacho

User Manual

Model INT4-I

4-20mA or 0-10V input integrated with respect to time. Switch between total and the instantaneous rate.

User Manual

Model INT4-L

Our most popular 1/8 DIN load cell panel meter has high precision and stability.

  • 4 or 6 wire load cell input
  • 10V @ 120mA excitation voltage (5V optional)
  • Up to 4mV/V as standard (10mV/V optional)

User Manual

Model INT4-T24

Accepts wireless data from the Mantracourt T24 wireless telemetry range.

Model INT4-P

As standard, the INT4-P is a process meter with 24V excitation voltage. When ordered with the POT option it becomes a 3 wire 0-10V input meter with 10V excitation for the potentiometer.

User Manual

Model INT4-P

Our most popular 1/8 DIN process panel meter has high precision and stability.

  • 4-20mA, 0-10V or 1-5V input
  • 24V @ 30mA excitation voltage (5V or 10V optional)
  • Adjustable 0-25 seconds filtering
  • Selectable 1, 2, 5, 10, 20 or 50 last digit round-up
  • Up to 10 points of user linearisation

User Manual

Model INT4-C

Quadrature mode allows you to scale a count and increase or decrease the value according to the sequencing of two pulses which are 90 degrees out of phase. This mode is ideal for measuring distance in pay-out/feed-in cable systems or direction in rotary systems.

User Manual

Model INT4-R

Ideal for measuring the resistance of a wide range of components such as…..

  • Motor windings
  • Incandescent lamp filaments
  • Heater element resistance
  • Inductors
  • Earth bonding
  • Solenoid coils
  • Relay coils
  • Servo coils

We use 4-wire measurement methods to ensure that the cable resistance is cancelled automatically from the measurement.

User Manual

Model INT4-S2

RS232 ASCII slave display.

User Manual

Model INT4-S4

RS422 or RS485 ASCII slave display.

User Manual

Model INT-T

Temperature display / controller accepting…..

  • 3-wire PT100 DIN
  • 3-wire PT100 ANSI
  • Thermocouple type J
  • Thermocouple type K
  • Thermocouple type N
  • Thermocouple type R
  • Thermocouple type S
  • Thermocouple type T

User Manual

General Specifications

Number of Digits 6
Digit Height 14mm
Digit Colour Red or optionally green
Bezel Size 96mm wide x 48mm high
Panel Cutout 92mm wide x 45mm high
Depth Behind Panel 125mm
Front Panel Sealing IP65 standard, IP67 with optional SPC4 cover
Power 95-265V AC or optionally 11-30V DC
Power Burden 10VA maximum
Storage Temperature -20C to +70C
Operating Temperature 0C to +50C

Output Options

Option ANB

Output: -10 to +10V
Drive Capacity: >1k Ohms
Accuracy: +/-20mV
Resolution: 16 bit D/A, better than 0.2mV

User Manual

Option ANI

Output: 4-20mA
Drive Capacity: <500 Ohms
Accuracy: +/-10uA
Resolution: 16 bit D/A, better than 0.4uA

User Manual

Option ANV

Output: 0-10V
Drive Capacity: >1k Ohms
Accuracy: +/-10mV
Resolution: 16 bit D/A, better than 0.2mV

User Manual

Option AL2

Format: 2 x SPST mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option AL4

Format: 4 x SPST mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option SPCO

Format: 2 x SPCO mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option DSS

Format: 2 x solid state relays
Contact Rating: 100mA max @ 250V AC or 500mA max @ 60V DC

Specify AC or DC relays at time of order.

User Manual

Option QSS

Format: 4 x solid state relays
Contact Rating: 100mA max @ 250V AC or 500mA max @ 60V DC

Specify AC or DC relays at time of order.

User Manual

Option 232

Output: RS232 ASCII

User Manual

Option 485

Output: RS422 / RS485 ASCII and Modbus ASCII

User Manual

Option RTU

Output: RS485 Modbus RTU

User Manual

Accessories

Once you have programmed the INT4 panel meter and locked out the settings, you can fit this optional plain lens to stop people from being tempted to push buttons.

INT4 digital panel meter plain lens

The SPC4 splash proof cover is designed to fit most makes of 1/8 DIN digital panel meters. It increases the front panel sealing to IP67 and provides impact protection.

Data Sheet

SPC4 splash proof cover

Our WALLBOX option showing an INT4 panel meter with SPC4 splash proof cover.

We can customise by adding pushbuttons, selector switches, LEDs, etc.

Technical Drawing

Wall mounting box for panel meters

The PCC range of cases are great for turning panel mounting meters into portable desktop units.

We can customise by adding pushbuttons, selector switches, LEDs, etc.

Data Sheet

PCC1 desktop enclosure for panel meters

Our DIN rail mounting option turns our INT4 panel meters into high precision signal conditioners for mounting inside control cabinets.

Data Sheet

DIN Rail Mounting Panel Meter

Applications

A crane overload monitoring and alarm system using INT4 digital panel meters.

A short video of a crane load display with visual and audible alarms using an INT4-P.

A group of INT4 digital panel meters in a batching control panel.

INT4 panel meters in batching control panel

An INT4-C counter mounted on a concrete batching vehicle.

As it is subjected to road spray from the wheels of the truck, it is protected by our IP67 cover. It also has daylight viewing LEDs so that it can be clearly read in sunlight.

INT4-C panel meter mounted on a concrete batching vehicle

A FUSION large digit display with 200mm high digits is summating the loads measured by 6 x INT4-L load cell panel meters.

Summation is digital with data collected over a 3-wire RS485 data link.

F8-6N-S4 and 6 x INT4-L panel meters

4 x INT4 digital panel meters DIN rail mounted inside a control cabinet for a filling line.

INT4 digital panel meters DIN rail mounted in control cabinet