MAXI-INT4 – Digital Panel Meters

MAXI-INT4 digital panel meter

Function / Input Type

Model MAXI-INT4-AH

Suits 50mV, 60mV, 75mV and 100mV shunts. Can be set to accumulate in a timebase of minutes, hours or days.

Model MAXI-INT4-C

Period mode is ideal for bake time and intervals.

User Manual

Model MAXI-INT4-H

Real time clock mode and up or down timing modes with 3 x contact closure control inputs.

  • Clock mode – HH:MM:SS
  • Day counter mode – number of days elapsed since last reset
  • HH:MM timer mode
  • MM:SS timer mode
  • SSSS timer mode
  • SSSSS.t timer mode
  • MMMM timer mode
  • HH:MM:SS timer mode
  • DD:MM:YY calendar mode
  • MM:DD:YY calendar mode

Model MAXI-INT4-C

Various counting modes.

  • Simple counting mode
  • Gated counting mode
  • 1 input with up/down control mode
  • 2 inputs up/down mode
  • 2 inputs up/up mode
  • 4 inputs up/up/down/down mode
  • 4 inputs up/up/up/up mode
  • 4 inputs down/down/down/down mode

Accepts different signal types and provides 24V DC sensor excitation as standard.

  • Contact closure
  • NPN
  • PNP/pushpull
  • TTL
  • CMOS
  • Passive coil
  • AC tacho

User Manual

Model MAXI-INT4-C

Rate mode is ideal for showing…..

  • Frequency
  • Flow rate
  • RPM
  • Instantaneous speed

Production rate mode is ideal for showing real production rates over longer periods.

Accepts different signal types and provides 24V DC sensor excitation as standard.

  • Contact closure
  • NPN
  • PNP/pushpull
  • TTL
  • CMOS
  • Passive coil
  • AC tacho

User Manual

Model MAXI-INT4-I

4-20mA or 0-10V input integrated with respect to time. Switch between total and the instantaneous rate.

Model MAXI-INT4-L

Our most popular 1/8 DIN load cell panel meter has high precision and stability.

  • 4 or 6 wire load cell input
  • 10V @ 120mA excitation voltage (5V optional)
  • Up to 4mV/V as standard (10mV/V optional)

User Manual

Model MAXI-INT4-P

As standard, the INT4-P is a process meter with 24V excitation voltage. When ordered with the POT option it becomes a 3 wire 0-10V input meter with 10V excitation for the potentiometer.

User Manual

Model MAXI-INT4-P

Our most popular 1/8 DIN process panel meter has high precision and stability.

  • 4-20mA, 0-10V or 1-5V input
  • 24V @ 30mA excitation voltage (5V or 10V optional)
  • Adjustable 0-25 seconds filtering
  • Selectable 1, 2, 5, 10, 20 or 50 last digit round-up
  • Up to 10 points of user linearisation

User Manual

Model MAXI-INT4-C

Quadrature mode allows you to scale a count and increase or decrease the value according to the sequencing of two pulses which are 90 degrees out of phase. This mode is ideal for measuring distance in pay-out/feed-in cable systems or direction in rotary systems.

User Manual

Model MAXI-INT4-R

Ideal for measuring the resistance of a wide range of components such as…..

  • Motor windings
  • Incandescent lamp filaments
  • Heater element resistance
  • Inductors
  • Earth bonding
  • Solenoid coils
  • Relay coils
  • Servo coils

We use 4-wire measurement methods to ensure that the cable resistance is cancelled automatically from the measurement.

Model MAXI-INT4-S2

RS232 ASCII slave display.

User Manual

Model MAXI-INT4-S4

RS422 or RS485 ASCII slave display.

User Manual

General Specifications

Number of Digits 6
Digit Height 20mm
Digit Colour Red or optionally green
Bezel Size 144mm wide x 72mm high
Panel Cutout 138mm wide x 67.5mm high
Depth Behind Panel 150mm
Front Panel Sealing IP54 standard, IP65 with optional SPC4M cover
Power 95-265V AC or optionally 11-30V DC
Power Burden 10VA maximum
Storage Temperature -20C to +70C
Operating Temperature 0C to +50C

Output Options

Option ANB

Output: -10 to +10V
Drive Capacity: >1k Ohms
Accuracy: +/-20mV
Resolution: 16 bit D/A, better than 0.2mV

User Manual

Option ANI

Output: 4-20mA
Drive Capacity: <500 Ohms
Accuracy: +/-10uA
Resolution: 16 bit D/A, better than 0.4uA

User Manual

Option ANV

Output: 0-10V
Drive Capacity: >1k Ohms
Accuracy: +/-10mV
Resolution: 16 bit D/A, better than 0.2mV

User Manual

Option AL2

Format: 2 x SPST mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option AL4

Format: 4 x SPST mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option SPCO

Format: 2 x SPCO mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option DSS

Format: 2 x solid state relays
Contact Rating: 100mA max @ 250V AC or 500mA max @ 60V DC

Specify AC or DC relays at time of order.

User Manual

Option QSS

Format: 4 x solid state relays
Contact Rating: 100mA max @ 250V AC or 500mA max @ 60V DC

Specify AC or DC relays at time of order.

User Manual

Option 232

Output: RS232 ASCII

User Manual

Option 485

Output: RS422 / RS485 ASCII and Modbus ASCII

User Manual

Option RTU

Output: RS485 Modbus RTU

User Manual

Accessories

The SPC4M splash proof cover increases the front panel sealing of the MAXI-INT4 to IP65 and provides impact protection.

SPC4M splash proof cover

The WALLBOXM option allows a MAXI-INT4 to be wall mounted and when used with the SPC4M splash proof cover, all round sealing is IP65.

We can customise by adding pushbuttons, selector switches, LEDs, etc.

Wall mounting box for MAXI-INT4